| 1209 Type Curtis to D&D Motors - Cross Reference Guide | |||||||||
| Click Tabs Below For other Types (1204,1205,1221) | |||||||||
| Curtis # | D&D # | Description | Voltage | Amps | Input Type | P-Amps | EMR-Rev | HPD | Adjust |
| 1209-4601 | 500P | 24-36 | 500 | 0-5K | 125 | 250 | Y | N/A | |
| 1209-4602 | 500P | 24-36 | 500 | 5K-0 | 125 | 250 | Y | N/A | |
| 1209-5501 | 500P | 36-48 | 450 | 0-5K | 100 | N/A | Y | N/A | |
| 1209-5503 | 500P | 36-48 | 450 | 0-5V | 100 | N/A | Y | N/A | |
| 1209-6401 | 450-72P | 48-72 | 400 | 0-5K | 100 | N/A | Y | N/A | |
| 1209-6403 | 450-72P | 48-72 | 400 | 0-5V | 100 | N/A | Y | N/A | |
| 1209-7201 | NA | 72-120 | 275 | 0-5K | 70 | N/A | Y | N/A | |
| 1209-7202 | NA | 72-120 | 275 | 0-5K | 70 | N/A | Y | N/A | |
| 1209B-4601 | 500P | 24-36 | 500 | 0-5K | 125 | N/A | Y | 3 | |
| 1209B-5501 | 500P | 36-48 | 450 | 0-5K | 125 | N/A | Y | 3 | |
| 1209B-5503 | 500P | 36-48 | 450 | 0-5K | 125 | N/A | Y | 3 | |
| 1209B-6402 | 450-72P | 48-72 | 400 | 0-5K | 100 | N/A | Y | 3 | |
| 1209B6405 | 450-72P | 48-72 | 400 | 0-5K | 100 | N/A | N | 3 | |
| 1209B-6A502 | NA | 48-80 | 400 | 0K-5 | 100 | N/A | N | 3 | |
| NOTES | |||||||||
| X Controllers: Emergency reverse option enhances plugging current when "belly button" is activated. | |||||||||
| HPD - Is a feature used in some applications that prevents operation if the keyswitch is turned on with the throttle applied | |||||||||
| Adjust - [ Adjust -- N/A-- No Adjustments] [ Adjust--2-- Accelaration ramp and plug current limit adjustable] | |||||||||
| [ Adjust--3--Acceleration ramp, plug current and drive current limit adjustable] | |||||||||